Product
ProductCurrent position > Product detail

Natural cyclone inlet vortex flowmeter

『Natural cyclone inlet vortex flowmeter』Related information(v cone flow meter|rotary gas meter|gallon meter|gear meter|metal tube rotameter|glass tube rotameter|nutating disk meter|transit time ultrasonic flow meter|wedge flow meter|pd meters|hydraulic flow meter|ultrasonic water flow meter|water flow meter|air flow meter|magnetic water flow meter|oxygen flow meter|gas flow meter|argon flow meter|air velocity meter|gasoline flow meter|fuel flow meter|ultrasonic water meter|digital water meter|nitrogen flow meter|solid flow meter|Oxygen tank flow meter|digital water flow meter|diesel fuel flow meter|steam flow meter|02 flow meter|compressed air flow meter|oil flow meter|liquid flow meter)

1. Regulations for Spiral Inlet Flow Meter

I need to clarify that the "spiral inlet flow meter" you mentioned should be a spiral inlet vortex flow meter, which is currently the official name commonly used in the industry. The following is a complete set of regulations for the operation and maintenance of vortex flowmeters: The core conclusion of the complete operation and maintenance regulations for vortex flowmeters is that this regulation is based on JJG 198-2014 "Verification Regulations for Velocity Flowmeters" and the latest product manual of flowmeter manufacturers, and is applicable to flow measurement calibration and daily operation and maintenance of single-phase fluids such as natural gas and air. 1. Installation and Calibration Regulations 1.1 Pre installation Requirements - Straight pipe sections should be retained before and after the flowmeter: upstream ≥ 10 times the pipe diameter length, downstream ≥ 5 times the pipe diameter length, to avoid strong interference sources such as elbows and valves - Installation environment should avoid strong electromagnetic interference areas and severe vibration areas, with an ambient temperature range of -20 ℃~60 ℃ (special customized models can reach -40 ℃~80 ℃) - The fluid should be completely filled in the pipeline without carrying a large number of bubbles or solid particles, and filters should be installed if the medium contains impurities. 1.2 Power on calibration process - Preheat for 15-30 minutes before starting the operation - Factory default parameters need to be reset according to the actual medium (natural gas/air/other gases), such as density and specific heat capacity - For the first use, a standard flow device is required for zero point calibr

Natural cyclone inlet vortex flowmeter
ation and Calibration of indication error, The error should be controlled within ± 1.5% (trade settlement level) Daily operating procedures 2.1 Startup process - Slowly open the upstream valve first, then slowly open the downstream valve to avoid fluid impact and damage to the sensor - Observe whether the flow rate, temperature, and pressure parameters on the display screen are normal, and put them into use officially without any alarm prompts. 2.2 Shutdown process - Close the upstream valve first, wait for the fluid in the pipeline to be emptied, and then close the downstream valve and equipment power supply - Long term shutdown requires disconnecting the power supply, emptying the residual medium in the pipeline, and taking rust prevention measures. 3 Daily Maintenance and Troubleshooting Procedures 3.1 Regular Maintenance Points - Check the pressure difference of the pipeline filter every 3 to 6 months. If the pressure difference exceeds 0.02 MPa, clean the filter element - Perform a parameter review every 12 months to confirm that the medium parameters have not changed - Conduct a comprehensive sealing inspection once a year to avoid medium leakage 3.2 Common Troubleshooting - No Flow Display: Check if the power connection and sensor wiring are loose, confirm if the fluid in the pipeline is flowing normally - Display Error is too large: Re calibrate the zero point, clean the impurities attached to the sensor inside, check if there is leakage in the pipeline - Frequent alarms: Check if the environmental vibration exceeds the standard, and confirm that the medium density parameter is set correctly. 4 According to the Metrology Law of the Peoples Republic of China, the vortex flowmeter used for trade settlement must und

『SILVER Official Website SERVICE』

Copyright2026SILVER E-Commerce
+86 15365082610